63A MCB has the ability to quickly respond and accurately cut off the circuit, which can effectively prevent electrical equipment from being damaged due to overload or short circuit. 63A MCB is compact, easy to install and reusable, reducing maintenance costs.63A MCB is widely used in circuit protection in various places such as industrial, commercial, high-rise and civil housing.
Standard |
Unit |
IEC/EN 60898-1 |
|
Electrical features |
Rated current In |
A |
1,2,4,6,10,16,20,25,32,40,50,63A |
Poles |
P |
1P,2P,3P,4P |
|
Rated voltage Ue |
V |
AC 230, 400 |
|
Insulation voltage Ui |
V |
500 |
|
Rated frequency |
Hz |
50/60 |
|
Rated breaking capacity |
A |
3000, 4500, 6000 |
|
Rated impulse withstand voltage(1.2/50) Uimp |
V |
4000 |
|
Dielectric test voltage at ind. Freq. for 1min |
kV |
2 |
|
Pollution degree |
|
2 |
|
Thermo-magnetic release characteristic |
|
B,C,D |
|
Mechanical features |
Electrical life |
t |
4000 |
Mechanical life |
t |
10000 |
|
Protection degree |
|
IP20 |
|
Reference temperature for setting of thermaI element |
ºC |
30 |
|
Ambient temperature (with daily average ≤35ºC) |
ºC |
-5~+40(Special application please refer to temperature compensation correction) |
|
Storage temperature |
ºC |
-25~+70 |
|
Installation |
Terminal connection type |
|
Cable/Pin-type busbar |
Terminal size top / bottom for cable |
mm2 |
25 |
|
|
AWG |
18-3 |
|
Terminal size top / bottom for busbar |
mm2 |
25 |
|
|
AWG |
18-3 |
|
Tightening torque |
N*m |
2 |
|
|
ln-Ibs. |
18 |
|
Mounting |
|
On DIN rail EN 60715(35mm)by means of fast clip device |
|
Connection |
|
From top and bottom |
Rated Current: 63A, indicating that the maximum current that this MCB can safely carry is 63 amps.
Rated Voltage: The rated voltage of the MCB may vary depending on the application and requirements, but it is usually suitable for circuits with AC 50/60Hz and rated voltage of 230/400V.
Number of Poles: The number of poles of MCBs may vary from model to model, and the common ones are single-pole (1P), double-pole (2P), three-pole (3P) and four-pole (4P). Among them, 4P indicates that this MCB is used for three-phase + N-wire circuits.
Household Circuit: It is suitable for the circuit protection of household electrical equipment, such as lighting, sockets and so on.
Commercial buildings: In commercial buildings such as shopping malls and office buildings, 63A MCB can be used to protect electrical equipment with larger loads.
Industrial: In industrial automation and
production lines, 63A MCB can be used to protect critical equipment and production line circuits.